Electrical design in Dubai: house with its wiring highlighted, an electrical model on a laptop, breakers and cable

Electrical design in Dubai

Electrical design in Dubai: load calculations for the DEWA application, single line diagrams, distribution boards, power and lighting layouts, earthing.

Message us on WhatsApp
10+
Years of experience
15
Specialists
6
Disciplines
90+
Projects

What the electrical design includes

The package follows the building type and stage of design, from a submission set for approval to detailed drawings for the contractor.

  1. 01Load schedule and calculation of the connected and demand load
  2. 02Single line diagram and distribution board schedules
  3. 03Power layouts: sockets, equipment and air conditioning units
  4. 04Lighting layouts, including emergency and exit lighting
  5. 05Earthing, equipotential bonding and lightning protection
  6. 06Cable sizing, voltage drop checks and material specifications
01

How electrical design is carried out

The engineer collects the architectural plans, the list of equipment and its ratings, and the client's requirements for lighting and controls. From this the load schedule is built and the main intake, the distribution boards and their locations are defined.

The design is coordinated with HVAC, plumbing and ELV drawings so that cable routes, risers and electrical rooms do not clash with ducts and pipes. Where a new connection or load increase is needed, the drawings and load details are prepared in the format the relevant authority and DEWA expect for review. The final set is what the contractor uses to procure materials and install the system.

02

Standby power and reliability

Some loads must keep running during a power outage: fire alarm and fire pumps, emergency lighting, lifts used for evacuation, server rooms and medical equipment. For these, the design includes separate circuits and, where required, a standby generator with an automatic transfer switch or a UPS.

For villas and small commercial units, the client decides which circuits to back up, such as refrigeration, security systems or part of the cooling. The engineer sizes the backup source and shows it clearly on the single line diagram.

03

Electrical design for Dubai conditions

Air conditioning is usually the largest load in a Dubai building, so the electrical design is developed together with the HVAC design rather than after it. High ambient temperatures reduce the current-carrying capacity of cables and the performance of switchgear in hot rooms and on roofs, which is taken into account in sizing and in the ventilation of electrical rooms.

Outdoor equipment, pool areas and coastal sites need suitable ingress protection and corrosion-resistant materials. The design follows DEWA regulations and the Dubai Building Code, with documents prepared to the requirements of the relevant authority for the plot.

04

What affects scope and timeline

The scope depends on the floor area and use of the building, the number of distribution boards and special systems, the need for standby power, and whether the work is a new building or a modification of an existing installation. An estimate is given after reviewing the drawings and requirements.

Process

How we run a project

A clear route from the first meeting to handover of the finished building.

  1. 1

    Consultation & site assessment

    We discuss the brief, budget and constraints, then survey and measure the site.

  2. 2

    Architectural design

    We develop the concept and a full set of project documentation.

  3. 3

    Approvals & permits

    We clear the government approvals and obtain the required permits.

  4. 4

    Estimate & planning

    We prepare a detailed cost estimate, a work schedule and a delivery plan.

  5. 5

    Construction & handover

    We build and supervise on site, then hand over the finished building with full documentation.

Questions and answers

Short answers to the questions clients ask most often before a project starts. If yours is not here, write to us and we will advise on your project.

Do I need an electrical design to get a DEWA connection?

Yes. A new connection or a load increase requires electrical drawings and a load calculation prepared to DEWA's requirements and submitted through the relevant process.

Can you design for a building that already exists?

Yes. The engineer surveys the existing installation, records what can be kept and prepares drawings for the changes, such as a new layout, extra load or upgraded boards.

Does the electrical design include ELV systems?

ELV systems such as CCTV, access control and data networks are usually a separate package. They can be designed together with the electrical drawings so that containment and power supplies are coordinated.

Is lighting design part of the electrical package?

General and emergency lighting layouts are included. Decorative lighting concepts for interiors and facades can be added as a separate scope.

Every remarkable project begins with a first step

From concept to delivery — we create architecture that unites aesthetics, function and engineering precision.

Message on WhatsApp