Fire fighting system design in Dubai
Fire fighting system design in Dubai: sprinklers, hose reels and landing valves, fire pumps and tanks, clean agent and kitchen suppression systems.
- 10+
- Years of experience
- 15
- Specialists
- 6
- Disciplines
- 90+
- Projects
Which fire fighting systems are designed
The choice of system follows the building use, the hazard in each space and the requirements of the UAE Fire and Life Safety Code.
- 01Wet sprinkler systems for retail, offices, car parks and hotels
- 02Deluge and water curtain systems for openings and special hazards
- 03Hose reels, landing valves and wet or dry risers
- 04Clean agent systems for server rooms, electrical rooms and archives
- 05Kitchen hood wet chemical suppression for restaurants
- 06Fire pump sets with jockey pumps and fire water tanks
- 07Fire department connections and external hydrants where required
How fire fighting system design is carried out
The engineer starts with the architectural plans, the use of each space and the fire strategy. The hazard classification of each area determines the design density, the operating area and the duration of water supply.
Hydraulic calculations then define pipe sizes, pump duty and the volume of the fire water tank. Sprinkler heads are placed to avoid obstructions from beams, ducts and lighting, which requires close coordination with the HVAC and electrical designers. The drawings, calculations and specifications are prepared for submission to Dubai Civil Defence through the relevant authority and for installation by the contractor.
Water, pressure and heat in Dubai
A fire fighting system cannot rely on mains pressure alone, so most buildings need a dedicated fire water tank and pump room. Their size and location are agreed early with the architect and structural engineer, because a full tank and pump set are heavy and take space in a basement or on the ground floor.
Pipes and valves in exposed or unconditioned areas face high temperatures, and water in tanks needs protection from heat and contamination. Coastal sites call for corrosion-resistant materials and coatings. Pipe supports and bracing are designed so that the network stays intact during the building's movement and thermal expansion.
Clean agent systems for server and electrical rooms
In server rooms, archives and electrical rooms, water would cause more damage than the fire itself. Here a clean agent system is used: the gas floods the room and suppresses the fire without harming equipment or documents.
The design calculates the agent quantity for the room volume, places the cylinders and nozzles, and checks that the room is tight enough to hold the concentration. It also includes the control logic: detection, a warning before discharge and interlocks with ventilation and doors.
What affects the cost of the design
The scope depends on the area and height of the building, the hazard classes, the number of different systems, the need for pump rooms and tanks, and whether the work is new construction or a modification of an existing system for a fit-out.
How we run a project
A clear route from the first meeting to handover of the finished building.
- 1
Consultation & site assessment
We discuss the brief, budget and constraints, then survey and measure the site.
- 2
Architectural design
We develop the concept and a full set of project documentation.
- 3
Approvals & permits
We clear the government approvals and obtain the required permits.
- 4
Estimate & planning
We prepare a detailed cost estimate, a work schedule and a delivery plan.
- 5
Construction & handover
We build and supervise on site, then hand over the finished building with full documentation.
Questions and answers
Short answers to the questions clients ask most often before a project starts. If yours is not here, write to us and we will advise on your project.
Does every building need automatic sprinklers?
No. The requirement depends on the building use, height and area under the UAE Fire and Life Safety Code. The designer checks which spaces need automatic protection and which can rely on hose reels and extinguishers.
Can you design fire fighting for an existing building?
Yes. The engineer surveys the existing system, checks pump and tank capacity and prepares drawings for the changes, including relocation of sprinklers for a new fit-out.
What is the difference between a sprinkler and a deluge system?
In a sprinkler system, only the heads exposed to heat open. In a deluge system all nozzles are open and water flows through all of them at once when the valve is triggered by the detection system.
Does a restaurant need a kitchen suppression system?
Commercial kitchens with cooking hoods typically require a wet chemical suppression system over the cooking line. It is designed together with the hood exhaust and gas shut-off.